AR  CZ  ES  FA  FR  HU  IT  JP  KR  PL  PT  RU  TR  CN 
Skip to main content

Acoustic systems for buildings with a thermally activated concrete core

Special requirements such as for construction projects with solid, activated concrete core ceilings (building element cooling) or buildings erected to low-energy standards mean it is not possible to cover the ceiling surfaces with acoustics materials; in response we have developed an acoustics system that makes it possible to make use of the thermal mass of both the ceilings and walls.

Inquire now

 

Advantages

  • Acoustics, fire protection and ecology combined to a universal panel material
  • Easy to install
  • It is possible to fulfil individual design aspirations using different formats and special colours

Special requirements such as for construction projects with solid, activated concrete core ceilings (building element cooling) or buildings erected to low-energy standards mean it is not possible to cover the ceiling surfaces with acoustics materials; in response we have developed an acoustics system that makes it possible to make use of the thermal mass of both the ceilings and walls.

Because in addition to air-conditioning aspects the room acoustics have an important role to play, the acoustic baffles are eminently suitable to achieve very good sound absorption. This construction design ensures a variable acoustic environment without impairing the function of the thermally active surfaces. The objective was to develop an ecologically safe, robust baffle system that it is possible to install in schools as well as in public buildings without any difficulty.

That is why we turned to our proven recycled glass granulate panel as the substrate.

Care / refurbishing:
It is possible to clean localized soiling using a damp synthetic sponge or brush. Clean with a vacuum cleaner and brush. Refurbishable by spraying with Wilhelmi acoustic paint (WAF-R), without any loss of sound absorption properties.

Standard sizes:
Standard lengths: 1250 mm
Standard heights: 200 mm, 300 mm and 400 mm
Custom formats on request.

Thickness:
18 mm

Building material class:
A2 non-combustible to DIN 4102

Surface:
Non-directional, fine pore structured colour coating

Surface colour:
White
Special colours on request

Light reflectance value:
(white) >90 % (diffuse: 0.9).

Humidity:
Permanent high levels of humidity (> 70%) affect the dimensional stability of the panels.

Acoustics:
The flexibility to determine the width as well as freely vary the arrangement of the baffles makes it possible to tailor the acoustic environment to suit the most widely varying demands.

Installation:
A construction was developed that can be both adapted directly on the ceiling using hat channels or installed affixed at a variable distance to the concrete ceiling utilizing different T-profile systems.
Special versions and property-specific solutions are possible on request.
 

Products from Lahnau Akustik offer numerous design options. We offer a huge choice of special colours and surfaces. We are happy to offer advice.

Surface:
Acoustic membrane with matt, smooth and non-directional surface, optionally available as sound absorbing (G) or sound reflecting (GT)

Surface colour (visible side):
In special colours as per sample on request; optional antistatic, water-repellent special coating

MIKROPOR® G
Non-directional, fine-pore structured colour coating light reflectance value (white) > 90% (diffuse: 0.9)

MIKROPOR® GT
This version as Mikropor G but sound reflecting.

MIKROPOR® G PATINA
Non-directional, matt, smooth coloured surface coating

(the colour and structure shown in images of surfaces can differ slightly from the original)

* Special colour

We would be more than happy to send you a sample.
Feel free to contact us.

The flexibility to determine the width as well as freely vary the arrangement of the baffles makes it possible to tailor the acoustic environment to suit the most widely varying demands.

We develop effective acoustic building materials in close cooperation with scientists, clients, architects and contractors. Utilizing these high-quality materials facilitates optimum speech intelligibility in our built-up environment.

At the same time, the design options available with regard to material, surface, colour and shape are so varied that it is possible to efficiently combine the demands placed on man and an eco-friendly architecture with one another on the basis of the latest scientific findings.

A variety of acoustics tests are available to download from the Download archive.

Installation

A construction was developed that can be both adapted directly on the ceiling using hat channels or installed affixed at a variable distance to the concrete ceiling utilizing different T-profile systems. Special versions or property-specific solutions are possible on request.

Overview
Baffle hanger in detail
Twist-on clip and panel holder
1. Cleaning
  • Before cleaning with a damp cloth, carefully remove surface dust with a brush or vacuum cleaner.
  • It is possible to remove localized soiling such as fingerprints or trails of soiling close to air outlets using a firm, damp sponge together with a commercially available household cleaner or Moisture-Clean (available as a powder from Lahnau Akustik) in the respective recommended concentrations.
  • Then carefully wash down the cleaned surface with clean, clear water and dab dry with an absorbent cloth or paper (kitchen roll).
  • We recommended you test clean an inconspicuous area each time before cleaning.

Professional refurbishment must be carried out using Wilhelmi acoustic paint WAF-R 86 (special colours WAF-R 87).

  • Quantity used during refurbishment: 400-700 g/m² depending on the degree of soiling
  • Ensure the room temperature does not fall below 12 °C when applying the coating; the relative humidity should not exceed 70%.
  • Once applied immediately ensure the rooms are ventilated and dehumidified.
2.1 Refurbishment

If the acoustic ceiling has become heavily soiled after many years of normal use and can no longer be cleaned properly, it is possible to restore it to a condition virtually as good as new by applying a refurbishment spray.

When applied professionally in accordance with the manufacturer’s instructions the acoustic absorbency of the wall or ceiling surface is not impaired. The refurbishment can be repeated several times, if required.

Under no circumstances should emulsion paints be applied to the surfaces using a brush or roller, otherwise the sound absorbing properties will be lost.

It is only possible to guarantee the acoustic characteristics will be retained by engaging a professional company that uses the appropriate coating machinery to professionally apply the refurbishment spray, e.g.,

Strobl Beschichtungstechnik GmbH
Hermann-Volz-Straße 50
D-88400 Biberach/Riß

Tel. +49 7351/4400-0
Fax +49 7351/4400-60

 

  • Schools & kindergartens
  • Theatres & concert halls
  • Banks & insurance offices
  • Private properties
  • Bars and restaurants
  • Hospitals
  • Office & administration
  • Indoor swimming pools

 

Quality management

It is possible to achieve continual improvement with the aid of quality management by involving all members of staff and optimizing company procedures across all departments. Fulfilling customer requirements is central to all we do. An integrated management system for quality, environment and occupational health and safety according to EcoStep.


Environment management

As a manufacturer of environmentally friendly products based on the raw materials glass and metal Lahnau Akustik GmbH is passionately committed to protecting the environment. We wish to contribute towards balancing economy and ecology with the aim of achieving a sustainable development taking into consideration the needs of people and nature.


The ecological benefits of acoustic panels made of recycled glass:

  • 100% recycled glass
  • Sustainable
  • Conserve natural resources
  • Winner of many ecological awards
  • Optimize your LEED rating
  • Healthy home environment “built-in”
  • Reduce CO2
  • Optimize heat insulation

With you in mind, we have introduced:

An integrated management system for quality, environment and occupational health and safety. An expert assessment documented in a report verifies that the management system fulfils

requirements and, as a consequence, the core stipulations of the following standards:
ISO 9001:2000
ISO 14001:2004
ILO guidelines on occupational safety and health (2001)